David Schäfer authoredf486698a
Configuration Files
The behaviour of SaQC is completely controlled by a text based configuration file.
Format
SaQC expects its configutation files to be semicolon-separated text files, with a fixed header. Each row of the configuration file lists one variable and one or several test functions, which will be evaluated to procduce a result for the given variable.
Header names
The header names are basically fixed, but if you really insist in custom configuration headers have a look here.
Name | Data Type | Description | Optional |
---|---|---|---|
varname | string | name of a variable | no |
test | function notation | test function | no |
plot | boolean (True /False ) |
plot the test's result | yes |
Test function notation
The notation of test functions follows the function call notation of Python and many other programming languages and looks like this:
range(min=0, max=100)
Here the function range
is called and the values 0
and 100
are passed
to the parameters min
and max
respectively. As we (currently) value readablity
of the configuration more than conciseness of the extrension language, only
keyword arguments are supported. That means that the notation range(0, 100)
is not a valid replacement for the above example.
Examples
Single Test
Every row lists one test per variable, if you want to call multiple tests on a specific variable (and you probably want to), list them in separate rows
varname | test |
---|---|
x |
missing() |
x |
range(min=0, max=100) |
x |
constant(window="3h") |
y |
range(min=-10, max=40) |
Multiple Tests
A row lists multiple tests for a specific variable in separate columns. All test
columns need to share the common prefix test
.
varname | test_1 | test_2 | test_3 |
---|---|---|---|
x |
missing() |
range(min=0, max=100) |
constant(window="3h") |
y |
range(min=-10, max=40) |
Plotting
As the process of finding a good quality check setup is somewhat experimental, SaQC
provides a possibility to plot the results of the test functions. In
order to opt-into this feture add the optional columns plot
and set it
to True
whenever you want to see the result of the evaluation. These plots are
meant to provide a quick and easy visual evaluation of the test setup and not to
yield 'publication-ready' results
varname | test | plot |
---|---|---|
x |
missing() |
|
x |
range(min=0, max=100) |
False |
x |
constant(window="3h") |
True |
y |
range(min=-10, max=40) |
Wildcards
Some of the most basic tests (e.g. checks for missing values or range tests) but
also the more elaborated functions available (e.g. aggregation or interpolation
functions) are very likely to be used on all or at least several variables of
the processed dataset. As it becomes quite cumbersome to list all these
variables seperately, only to call the same functions with the same
parameters over and over again, SaQC supports wildcards and regular expressions
within the varname
column.
varname | test |
---|---|
* | harmonize_shift2Grid(freq="15Min") |
(x | y) | missing() |
Bring it to a file
As mentioned above SaQC, expectd the configuration to be a table-like, semicolon-separated text file. So the configuration from the plotting-example above needs to be written as:
varname;test;plot
x;`missing()`;
x;`range(min=0, max=100)`;False
x;`constant(window="3h")`;True
y;`range(min=-10, max=40)`;